• High Efficiency Filter Outlet HEPA Box with Smooth Diffuser Plate for Pharmaceutical Cleanroom Air Filter HEPA Filter for Clean Room
  • High Efficiency Filter Outlet HEPA Box with Smooth Diffuser Plate for Pharmaceutical Cleanroom Air Filter HEPA Filter for Clean Room
  • High Efficiency Filter Outlet HEPA Box with Smooth Diffuser Plate for Pharmaceutical Cleanroom Air Filter HEPA Filter for Clean Room
  • High Efficiency Filter Outlet HEPA Box with Smooth Diffuser Plate for Pharmaceutical Cleanroom Air Filter HEPA Filter for Clean Room
  • High Efficiency Filter Outlet HEPA Box with Smooth Diffuser Plate for Pharmaceutical Cleanroom Air Filter HEPA Filter for Clean Room

High Efficiency Filter Outlet HEPA Box with Smooth Diffuser Plate for Pharmaceutical Cleanroom Air Filter HEPA Filter for Clean Room

After-sales Service: 24 Hours Online
Warranty: Within 30 Years
Feature: Environmental, Fireproof, Light Weight, Metal Panel
Fire Rating: 1
Certification: CCC, ROHS, ISO9001
Customized: Customized
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Basic Info.

Model NO.
JEDHA-904
Length
Any Length
Color
Ral Color
Width
950,1150,980
Thickness
40mm,50mm,75mm,100mm,150mm,200mm
Use
Roof, Wall for House,Office,Warehouse,Factory
Steel Thickness
0.3-0.8mm
Surface
Steel, Stainless, PVC
Density
8-40kg/M3
Application
Ceiling,Cleanroom,Cold Room,Partition,Roof,Wall
Advantage
Waterproof, Fireproof
Peculiarity
Easy Installation
Core Material
EPS,PU,Rock Wool
Structure
Assembled
Certificate
ISO,SGS
Panel Material
Metal
Transport Package
Sea Packing
Specification
50, 75, 100, 150
Trademark
Jedha
Origin
China
HS Code
730890
Production Capacity
700000 Meter/Month

Product Description

 

The high-efficiency air outlet is an ideal terminal filtering device for the thousand-, ten-, and one-hundred-thousand-level purification air-conditioning systems, and can be widely used in clean air-conditioning systems in industries such as medicine, health, electronics, and chemical. The high-efficiency air outlet is used as a terminal filtering device for the transformation and construction of clean rooms of Class 1,000, Class 10,000, and Class 100,000, and is the key equipment to meet the requirements of cleanliness. The high-efficiency air outlet includes static pressure box, diffuser plate, high-efficiency filter, and the interface with the air pipe can be a top or side connection.

 

Features

1. The box body is welded with high quality cold rolled steel panel (electrostatic spraying) or stainless steel panel. Through special leakproof structure design and combined with special treatment of all welding lines, the possible leakage problem of the box body is avoided.

2. The fixation method of the diffuser panel is generally divided into side fixation and bottom fixation. Customers can choose according to their own requirements.

3. The filter stationary frame is made of the whole plate, which ensures the flatness of the filter fixed surface and effectively prevents air leakage.

4. Special filter press device can fix the filter well on the installation position, and it is easy to disassemble and install.

5. HEPABOX can be used for in-situ detection. Filter integrity test interface is reserved on the box, and PAO/DOP test can be conducted directly in the room.

6. HEPABOX can be used for in-situ inspection. The filter integrity test interface is reserved on the box, and PAO/DOP testing can be performed directly indoors.

7. Adjust valve and insulation layer can be installed according to user requirements.

In order to ensure the filtration efficiency of the filter and the cleaning effect of the cleaning system, the high efficiency filter installation must comply with the requirements of clean room construction and acceptance code or design drawing.

High Efficiency Filter Outlet HEPA Box with Smooth Diffuser Plate for Pharmaceutical Cleanroom Air Filter HEPA Filter for Clean Room

1. Preparation before installation in order to prevent hepa from being polluted, the air cleaning system must be installed after the unpacking inspection and installation. The air conditioner, hepa box, air duct and clean room must be cleaned.Before installation, check the flatness of the end face of the filter frame or edge mouth, and the allowable deviation of the flatness of the end face should be no more than 1mm each.

 

If the flatness of the end surface exceeds the allowable deviation, only the frame end surface of the filter installation is allowed to be modified or adjusted, and the outer frame of the filter itself is not allowed to be modified, otherwise the filter material or sealing part in the filter will be damaged, reducing the filtering effect.

 

2. Installation requirements when installing hepa filters, ensure that the direction of airflow is consistent with the arrow mark on the outer frame.High efficiency filters assembled with corrugated plates must be vertically mounted, not in reverse.The high efficiency filter and the frame of the assembly high efficiency filter are usually sealed by the jacking method and the pressing method.

High Efficiency Filter Outlet HEPA Box with Smooth Diffuser Plate for Pharmaceutical Cleanroom Air Filter HEPA Filter for Clean Room

 

Graph of Initial Pressure Drop versus Face Velocity

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2021

Suppliers with verified business licenses

Plant Area
>2000 square meters
Management System Certification
ISO 9001, ISO 14001
OEM/ODM Availability
Yes